Skip Navigation

Forestry 2003 76(4):425-436; doi:10.1093/forestry/76.4.425
© 2003 by Institute of Chartered Foresters
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (1)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Kerr, G.
Right arrow Articles by Mason, B.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

A sampling system to monitor the transformation from even-aged stands to continuous cover

Gary Kerr1, Roger Boswell1 and Bill Mason2

1 Forest Research, Alice Holt Lodge, Wrecclecsham, Farnham, Surrey GU10 4LH, England 2 Forest Research, Northern Research Station, Roslin, Midlothian EH25 9SY, Scotland

The paper describes work carried out to devise a system of monitoring the change from even-aged management to continuous cover. The application of the system is described in Forestry Commission Information Note 45 (Kerr et al., 2002). It uses systematic grid sampling with plot size selected to assess a minimum number of trees, depending on the area of the management unit, and was designed by carrying out a number of simulations based on data for theoretical and real stands of trees. It was field tested in two woodlands being transformed to continuous cover, both of which had a mixture of tree sizes and a range of species. The results of these studies suggest that the proposed sampling system will give an adequate representation of the trees in a stand in terms of diameter distribution and species proportions. However, the ability of the sampling system to collect data on sapling regeneration was not fully tested and requires further work.


Received 30 September 2002.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.